3.3
Steam buffer and condenser buffer.
The RAN-concept includes two types of energy storage. The storage
is called Steam buffer and Condenser buffer. The steam buffer
is a high temperature storage that will offer several attractive
features in automotive applications as well as small scale CHP.
The steam buffer makes it possible to design the steam generator
for only average power out put. High electric and hot water peak
power can be obtained by the steam buffer. The steam buffer smoothing
the combustion and enable optimizing of the combustion to avoid
environmental harmful emissions. The steam buffer can also be
used to store low tariff electricity during nights. The steam
buffer unfolds also new possibilities for solar thermal energy
applications when it can store the solar energy until occasion
when the sun is not shining .The Steam Buffer also makes it possible
to matching the mismatch between the electricity and heat demand.
Further more Steam Buffer will imply reduced risk for outages
when there will be steam available to propel the steam engine
even if the burner will break down.
The condenser buffer makes is possibly to condense large amount
of steam at a high rate without noise which is important in all
kind of applications. For more detailed information see separate
document
|